Method

Advantages & outcomes

Limitations

DW

• Can determine the co-administered ASP &ROX successfully in different matrices

• Applied on zero order spectra, consequently less noise is obtained

• No need for further manipulation so, it does not require special software

• Has the least mathematical slope & intercept of linear equation, so low interference and error index are assured

• Has RSD% less than 2 which offers accurate and precise determinations

• Applied on Zero order spectra, so some minor features of the spectra may be neglected

• The wavelength pairs of choice may be critical which propose meticulous analysis

RD

• Can determine the co-administered ASP &ROX successfully in different matrices

• Applied on ratio spectra, that keeps the potential interference constant throughout the whole spectrum

• Allow wide choice of wavelength pairs for determination

• Critical determinations are avoided

• Has low mathematical slope & intercept of linear equation, so low interference and error index are obtained

• Has RSD% less than 2 which offers accurate and precise determinations

• Ratio spectra may enhance base line noise

• It needs one more manipulation step

• It requires divisor selection optimization

1DD

• Can determine the co-administered ASP &ROX successfully in different matrices

• Applied on ratio spectra, that keeps the potential interference constant throughout the whole spectrum

• Derivatization cancels the interfering contribution throughout the spectra

• Derivative manipulation may enhance some minor features that permit clear determination

• Allow variable wavelengths for quantitation

• Has low mathematical slope & intercept of linear equation, so low interference and error index are obtained

• Creates new sensitive analytical signals giving the chance of more sensitive results

• Has RSD% less than 2 which offers accurate and precise determinations

• Ratio spectra with derivative steps may enhance base line noise

• It needs more manipulation steps

• It requires divisor and derivatization parameters optimization