Skip to main content

Table 1 The regression and validation parameters for the proposed spectroscopic methods for the determination of ALC and OLO

From: Determination of antihistaminic drugs alcaftadine and olopatadine hydrochloride via ion-pairing with eosin Y as a spectrofluorimetric and spectrophotometric probe: application to dosage forms

Parameter

Method A

Method B

Method C

Method D

Linear range (µg mL−1)

0.15–2.0

0.8–8.0

0.20–2.0

1.0–10

Slope

0.415

0.091

0.384

0.049

SD of slope (Sb)

5.10

0.0013

0.005

0.0005

Intercept

0.76

0.0086

0.94

− 0.001

SD of intercept (Sa)

5.75

0.0059

5.301

0.003

Correlation Coefficient

0.9997

0.9996

0.9996

0.9997

SD of residuals (Sy, x)

8.20

0.00031

7.56

0.004

LOD

46.67 ng mL−1

0.21 µg mL−1

45.52 ng mL−1

0.21 µg mL−1

LOQ

138.40 ng mL−1

0.65 µg mL−1

137.93 ng mL−1

0.63 µg mL−1