Table 3 Regression and validation parameters of the proposed methods for determination of guaiafenesin, bromhexine, salbutamol and guaiacol

From: Chromatographic analysis of triple cough therapy; bromhexine, guaiafenesin and salbutamol and pharmaceutical impurity: in-silico toxicity profile of drug impurity

Parameters

TLC

HPLC

GUF

BR

SAL

GUL

GUF

BR

SAL

GUL

Calibration range

0.50–8.00

μg/band

0.25–4.00

μg/band

0.25–4.00

μg/band

0.10–1.60

μg/band

2.00–50.00 μg/mL

Slope

1615.60

2779.20

1556.40

3723.30

0.2082

0.1328

0.1428

0.2031

Intercept

2547.20

2426.00

716.89

733.65

−  0.0560

−  0.1091

0.0907

−  0.3102

Correlation coefficient (r2)

0.9998

0.9998

0.9999

0.9999

0.9999

0.9999

0.9999

0.9999

Accuracy (%R)

98.59

99.84

99.76

99.82

99.77

99.83

99.09

99.20

Repeatability (%RSD)a

0.79

0.71

0.93

0.39

1.42

0.87

1.27

1.47

Intermediate precision(%RSD)a

1.00

0.81

1.32

0.99

1.77

1.04

1.34

1.54

LODb

0.16

0.07

0.08

0.02

0.56

0.61

0.51

0.59

LOQc

0.48

0.21

0.24

0.06

1.70

1.83

1.53

1.78

  1. Where SD is the standard deviation of the intercept and slope is the slope of the calibration graph
  2. aThe intra-day and inter-day precision (n = 9), %RSD of three distinct concentrations; 1, 4 and 6 μg/band (for GUF), 0.5, 2, and 3 μg/band (for BR and SAL), 0.2, 0.8, and 1.4 μg/band (for GUL) for TLC-densitometeric method. For HPLC method, concentrations applied were; 3, 15 and 30 μg/ mL for all components
  3. bLOD = (SD of the intercept /slope) × 3.3
  4. cLOQ = (SD of the intercept /slope) × 10