Table 5 Corrosion parameters for Al corrosion in one molar HCl with and without MOFs concentrations

From: Experimental and theoretical studies of the efficiency of metal–organic frameworks (MOFs) in preventing aluminum corrosion in hydrochloric acid solution

Comp

Conc. ppm

icorr. µA/ cm2

Ecorr., mV/SCE

βa mV/dec

c mV/dec

C.R mpy

θ

η%

Blank

0.0

5.714

566.86

2981

136.8

186.58

MOF1

100

4.965

737.36

586.8

134.8

162.12

0.131

13.1

200

2.719

731.39

224.5

99.0

61.164

0.524

52.4

300

1.873

738.62

128.1

75.4

43.973

0.672

67.2

400

1.347

740.45

309.4

117.4

88.789

0.764

76.4

MOF1@TiO2

100

1.936

533.03

84.0

58.2

25.522

0.694

69.4

200

1.793

601.50

204.7

109.1

58.564

0.716

71.6

300

1.631

737.38

176.1

79.3

63.219

0.742

74.2

400

0.750

735.07

161.8

99.1

53.248

0.876

86.9