Skip to main content

Table 9 Evaluation of the accuracy of the proposed HPLC method (method A) for the determination of Vitamin D3 by standard addition on Ultracalce®capsules

From: Development of chromatographic methods to determine multivitamins formulation depending on their solubility and polarity: comparative study using three greenness assessment tools

Claimed Conc of Vit D3 taken from capsule in (µg/mL)

%Found Conc. ± RSD*

Std. Conc. Added (µg/mL)

Total recovered Conc(µg/mL)

Recovered Conc of standard added (µg/mL)

% Recovery

1

107.67% ± 1.57

2

3.09

2.01

100.5

5

6.11

5.03

100.6

15

16.28

15.2

101.33

  1. *Average of three determinations