Skip to main content

Table 7 Evaluation of the accuracy of the proposed HPLC method (method A) for the determination of Pyridoxine hydrochloride by standard addition on Ultracalce®capsules

From: Development of chromatographic methods to determine multivitamins formulation depending on their solubility and polarity: comparative study using three greenness assessment tools

Claimed Conc of Py taken from capsule in (µg/mL)

%Found Conc. ± RSD*

Std. Conc. Added (µg/mL)

Total recovered Conc(µg/mL)

Recovered Conc of standard added (µg/mL)

% Recovery

10

93.45% ± 1.16

10.00

19.23

9.88

98.8

20.00

29.37

20.02

100.1

30.00

39.44

30.09

100.3

  1. *Average of three determinations