Parameter | Spectrophotometric methods | ANN method | ||||
---|---|---|---|---|---|---|
Direct | Isoabsorptive | Ratio subtraction | ||||
AML | OLM | HCT | AML | OLM | HCT | |
Accuracy (mean ± RSD) | 99.89 ± 0.937 | 101.96 ± 0.622 | 99.55 ± 1.889 | 100.47 ± 1.197 | 99.9 ± 1.066 | 100.75 ± 2.072 |
Repeatabilitya | 0.552 | 0.829 | 0.587 | 1.321 | 1.061 | 1.144 |
Intermediate precisionb | 0.925 | 1.327 | 1.593 | 1.119 | 1.683 | 2.424 |
Linear range (μg mL-1) | 5-40 | 2.5-40 | 5-40 | 3-40 | 2.5-40 | 5-40 |
Slope | 0.011 | 0.041 | 0.010 | 1.012 | 0.976 | 0.998 |
Intercept | 0.003 | 0.077 | 0.01 | −0.035 | 0.390 | 0.041 |
Correlation coefficient (r) | 0.9999 | 0.9989 | 0.9999 | 0.9992 | 0.9995 | 0.9995 |
LOD (μg mL-1) | 1.278 | 0.729 | 0.819 | 0.291 | 0.683 | 0.444 |
LOQ (μg mL-1) | 4.217 | 2.209 | 2.482 | 0.880 | 2.070 | 1.345 |